Working Principle of Double Acting Pneumatic Actuator

Working Principle of Double Acting Pneumatic Actuator.jpg

CCW
Air to Port A forces the pistons outwards, causing the pinion to turn counterclockwise while the air is being exhausted from Port B.

 

Air to Port B forces the pistons inwards, causing the pinion to turn clockwise while the air is being exhausted from Port A.

Working Principle of Double Acting Pneumatic Actuator.jpg

CW
Air to Port A forces the pistons outwards, causing the pinion to turn clockwise while the air is being exhausted from Port B.

 

Air to Port B forces the pistons inwards, causing the pinion to turn counterclockwise while the air is being exhausted from Port A.