COVNA Knife Gate Valve

Explore our extensive selection of knife gate valves, available in both electric and pneumatic configurations. These valves are specifically designed for handling highly concentrated or viscous media, offering reliable and efficient flow control solutions for a wide range of industrial applications.

What Is Knife Gate Valve?

A knife gate valve is a valve used to handle particles, or corrosive, viscous media, providing fully open and fully closed services. Easy to operate, simple design andsavespace.

The knife gate valve has stainless steel and corrosion-resistant knife, which can be effectively used in industries with corrosive media and can cut off impurities and is not easy to block. Long life span.

  • Paper and pulp
  • Power plant
  • Chemical
  • Cement plant
  • Wastewater treatment
  • and other applications

Material Table of Main Parts Of Knife Gate Valve:

1. Valve Body 2. Gate
3. Valve Seat 4. O-ring
5. Valve Seat Cover 6. Packing
7. Pacing Gland 8. Brackte
9. Valve Stem 10. Valve Stem Nut
11. Bearing 12. Support

 

 


Technical Parameter Of Electric Knife Gate Valve:

The valve body of the electric knife gate valve adopts an integral design, with low fluid resistance and flexible and convenient operation. The screw drive of the valve adopts a double-plane bearing design, which greatly reduces the transmission friction and facilitates the opening and closing of the valve.

Actuator Type Multi-turn Electric Actuator
Conventional Power Supply Three-phase: AC380V
Input Signal 4mA~20mA
Protection Class IP65, IP68
Size Range(Inch) DN50 to DN2000 (2″ to 80″)
Pressure 10 / 16 bar (145 / 232 psi)
Temperature -10℃ to 400℃ (14°F to 752°F )
Connection Options Flanged or Lugged
Valve Material Cast Iron or Stainless steel 304/316/316L
Seal Material PTFE, Metal hard seal or hard alloy
Flanged Standard ANSI B16.5, GB/T9113, JB/T79, HG, SH, JIS, DIN, NF, BS

Technical Parameter Of Pneumatic Knife Gate Valve:

The pneumatic knife gate valve consists of a pneumatic actuator and a knife gate valve. The knife gate valve is light and flexible in operation, small in size, smooth in passage, small in flow resistance, light in weight, easy to install and easy to disassemble.

Actuator Type Pneumatic Cylinder (Double Acting or Single Acting Actuator)
Size Range(Inch) DN50 to DN2000 (2″ to 80″)
Pressure 10 / 16 bar (145 / 232 psi)
Temperature -10℃ to 400℃ (14°F to 752°F )
Connection Options Flanged or Lugged
Valve Material Cast Iron or Stainless steel 304/316/316L
Seal Material PTFE, Metal hard seal or hard alloy
Flanged Standard ANSI B16.5, GB/T9113, JB/T79, HG, SH, JIS, DIN, NF, BS

Technical Parameter Of Knife Gate Valve:

COVNA knife gate valve with features of full bore design, low resistance and easy maintenance, two-way circulation, good wear resistance and soft seal and hard seal are optional

Operated Type Hand Wheel
Size Range(Inch) DN50 to DN2000 (2″ to 80″)
Pressure 10 / 16 bar (145 / 232 psi)
Temperature -10℃ to 400℃ (14°F to 752°F )
Connection Options Flanged or Lugged
Valve Material Cast Iron or Stainless steel 304/316/316L
Seal Material PTFE, Metal hard seal or hard alloy
Flanged Standard ANSI B16.5, GB/T9113, JB/T79, HG, SH, JIS, DIN, NF, BS

Dimension Of Knife Gate Valve:

1.Oil and Gas Industry

Pipeline Flow and Pressure Control: Used for flow and pressure control in natural gas and oil pipelines to ensure stability during transportation.
Gas and Liquid Distribution Systems: Regulates the flow of gases or liquids, ensuring precise control under various operating conditions.
Automation of Distribution Systems: Used in refineries and natural gas processing plants to automate fluid distribution and regulate the reaction processes.

2.Chemical and Petrochemical Industry

Reactor Pressure and Flow Control: Used in chemical reactors, storage tanks, and other equipment to control pressure and flow, ensuring stability in the chemical reaction process.
Flow/Pressure Regulation: Regulates the flow of liquids or gases in processes such as polymerization, refining, and distillation to ensure efficient production.
Steam Control: Regulates the flow and pressure of steam in steam generators and distribution systems.

3.Water and Wastewater Treatment

Water Flow Control: Regulates water flow and pressure in water supply and wastewater treatment systems to ensure normal operation.
Gas and Chemical Additions: Regulates the flow of chemicals or gases (such as chlorine or ammonia) added during the water treatment process.

4.HVAC (Heating, Ventilation, and Air Conditioning) Systems

Temperature Control and Airflow Regulation: Used in air conditioning systems to regulate the flow of cooling or heating fluids to maintain the desired temperature.
Pressure and Airflow Regulation: Adjusts the flow and pressure of air in ventilation, air conditioning, and humidification systems to ensure indoor comfort.

5.Food and Beverage Industry

Liquid Flow Control: Precisely controls the flow of liquids in processes such as brewing, dairy production, and beverage bottling.
Temperature and Pressure Regulation: Regulates temperature and pressure during heating, cooling, and sterilization to ensure product quality and safety.

6.Pharmaceutical Industry

Precision Flow Control: Regulates the flow of liquids and gases in pharmaceutical manufacturing processes to ensure precise control of process parameters.
Pressure Control: Adjusts pressure in cleaning and sterilization systems to ensure stable system operation.

7.HVAC Systems

Airflow and Temperature Control: Controls the flow and temperature of air to adjust environmental conditions, ensuring comfort and energy efficiency inside buildings.

8.Steel and Metallurgical Industry

Gas Flow Control: Precisely adjusts the flow of gases such as oxygen and nitrogen during smelting and heating processes to ensure stable furnace temperatures and chemical reactions.
Cooling Fluid Flow Regulation: Regulates the flow of cooling fluids in cooling systems to ensure temperature control of equipment.

9.Thermal and Power Industry

Steam and Water Flow and Pressure Control: Regulates the flow of steam and water in boiler systems, heat exchangers, and power plants to ensure efficient operation of thermal systems.

10.Mining Industry

Slurry Flow Regulation: Adjusts the flow and pressure of slurry during transportation and separation processes to ensure efficient extraction and processing of minerals.

The actuator on my automated valve operates, but the valve won’t turn. Why?

Most likely the valve stem or actuator coupling is broken.

The electric actuator limit switches or the pneumatic actuator position stops are not correctly adjusted.

Probably because there is no air pressure to the solenoid or dirt has jammed it. Also, debris might be trapped inside the valve. Or, the air pressure is not sufficient to operate the actuator. Remember: measure air pressure at the actuator, not at the compressor.

Maybe. First, be sure that the actuator torque output is sufficient to turn the valve reliably. Second, you will have to fabricate a custom mounting bracket and coupling to connect the actuator to the valve.

The valve will stop somewhere between full open and close. When power is reapplied to the original circuit, the actuator will complete the cycle.

To make the change just remove the actuator from the valve and turn it, or the valve stem, 90 degrees and remount the actuator.

Remove the actuator from the valve and check the valve stem. Most ball valves have stem flats at right angles to the flow when the valve is in the off position. On butterfly valves check the stem flow arrow marking.

Remove the actuator from the valve and check the valve stem. Most ball valves have stem flats at right angles to the flow when the valve is in the off position. On butterfly valves check the stem flow arrow marking.

Check the electric wiring schematic that came with the actuator for the correct hookup. Sometimes a copy is inside the actuator cover. If it is missing, don’t guess about the connections. Call the manufacturer for a schematic.

The actuator is wired incorrectly (check the schematic accompanying the actuator), or the external control switch is not the correct type for the actuator.

Not unless you bought it with an optional speed control.

Actuators and solenoid valves require different types of electrical control switches. SPDT for actuators, SPST for solenoids. Check the actuator wiring schematic for the correct wiring and switch type.