COVNA 2W31 Brass Water Solenoid Valve – Direct Acting

2W31 Brass Water Solenoid Valve

with high-frequency direct lifting diaphragm construction. Open from 0 bar with a large flow rate. Applied to low-pressure system. Available in 12v dc, 24v dc, 24v ac, 110v ac and 220v ac. 2 materials for your choice, brass and stainless steel. Suitable for water, air, oil, gas, etc. Widely used in various automatic applications. Available in G and NPT threads.

COVNA is committed to being your No.1 solenoid valve manufacturer and we will help you to choose the right and quality solenoid valve basic on your requirements. Inquiry us to get the best price!

Model

  • Function: Normally Closed
  • Pressure: 0 to 10bar
  • Voltage: DC-12V, 24V; AC-24V, 120V, 240V/60Hz; 110V, 220V/50Hz
  • Temperature of Media: -10 to 80℃ (14℉ to 176℉)
  • Suitable Media: Water, Air, Oil, Gas, etc
  • Material: Brass

Features Of 2W31 Brass Solenoid Valve

● Direct lifting diaphragm construction with high frequency.

● Open from 0 bar with a large flow rate.

● Responsive, fast opening or closing.

●Easy to install. Available in threaded and flanged connections.

● Normally open and normally closed are available.

● Suitable for water, oil, air and other general mediums.

● Widely used for various applications such as water treatment, car wash systems, automatic equipment, and so on.

Technical Parameters of 2W31 Brass Solenoid Valve

Port size3/8″, 1/2″, 3/4″, 1″, 1¼”, 1½”, 2″Orifice(mm)10, 15, 20, 25, 32, 40, 50
Port ThreadG, BSPP, BSPT, NPTFunctionNormally Closed
Pressure0 to 10 bar (145psi)VoltageDC-12V, 24V; AC-24V, 120V, 240V/60Hz; 110V, 220V/50Hz
Temperature of Media-10 to 80℃ (14℉ to 176℉)Suitable MediaWater, Air, Oil, Gas, Gas, Fuel, etc
MaterialsBrassApplicationsWater treatment, automatic machines, etc

 

SizePort SizeOrificeCvMin PressureMax Pressure
AC(22VA)DC(17W)
2W31-103/8″104.50.0 MPa0.7 MPa0.7 MPa
2W31-151/2″154.50.0 MPa0.7 MPa0.7 MPa
2W31-203/4″209.30.0 MPa0.7 MPa0.7 MPa
2W31-251″25120.0 MPa0.7 MPa0.7 MPa
AC(28VA)DC(36W)
2W31-321 1/4″32240.0 MPa1.0 MPa1.0 MPa
2W31-401 1/2″40290.0 MPa1.0 MPa1.0 MPa
2W31-502″50480.0 MPa1.0 MPa1.0 MPa

Dimension of 2W31 Brass Solenoid Valve

Port Size3/8”~2”Orifice(mm)15, 20, 25, 32, 40, 50
Port ThreadBSPP, BSPT, NPT, FLANGEFunctionNormally closed or opened
Pressure0-1.0 MPa (10 bar)VoltageDC-12V, 24V; AC-24V, 120V, 240V/60Hz; 110V, 220V/50Hz
Temperature of media-10~100℃ (14℉ to 212℉)Suitable MediaWater, gas, oil, etc
MaterialBrass, Stainless SteelSealing MaterialNBR, VITON, PTFE, EPDM
CoilS51B,30VA(AC),24W(DC),IP65,100%ED
CoilSD01B,28VA(AC),36W(DC),IP65,100%ED
The actuator on my automated valve operates, but the valve won’t turn. Why?

Most likely the valve stem or actuator coupling is broken.

The electric actuator limit switches or the pneumatic actuator position stops are not correctly adjusted.

Probably because there is no air pressure to the solenoid or dirt has jammed it. Also, debris might be trapped inside the valve. Or, the air pressure is not sufficient to operate the actuator. Remember: measure air pressure at the actuator, not at the compressor.

Maybe. First, be sure that the actuator torque output is sufficient to turn the valve reliably. Second, you will have to fabricate a custom mounting bracket and coupling to connect the actuator to the valve.

The valve will stop somewhere between full open and close. When power is reapplied to the original circuit, the actuator will complete the cycle.

To make the change just remove the actuator from the valve and turn it, or the valve stem, 90 degrees and remount the actuator.

Remove the actuator from the valve and check the valve stem. Most ball valves have stem flats at right angles to the flow when the valve is in the off position. On butterfly valves check the stem flow arrow marking.

Remove the actuator from the valve and check the valve stem. Most ball valves have stem flats at right angles to the flow when the valve is in the off position. On butterfly valves check the stem flow arrow marking.

Check the electric wiring schematic that came with the actuator for the correct hookup. Sometimes a copy is inside the actuator cover. If it is missing, don’t guess about the connections. Call the manufacturer for a schematic.

The actuator is wired incorrectly (check the schematic accompanying the actuator), or the external control switch is not the correct type for the actuator.

Not unless you bought it with an optional speed control.

Actuators and solenoid valves require different types of electrical control switches. SPDT for actuators, SPST for solenoids. Check the actuator wiring schematic for the correct wiring and switch type.