COVNA 2W31 Brass Solenoid Valve With LED Light – Direct Acting

2W31 Brass Solenoid Valve With LED Light

when the valve is working and the LED light will turn on. Available in 3/8 inches to 2 inches. Fast acting and zero leakage. Pure copper coil & Low-temperature rise. Well for fluid control. As a solenoid valve supplier, we provide all types of solenoid valves for your project such as waterproof type, high-pressure type, general purpose type, etc. Inquiry us to get the best price!

Model

  • Function: Normally Closed
  • Pressure: 0 to 10 bar
  • Voltage: DC-12V, 24V; AC-24V, 120V, 240V/60Hz; 110V, 220V/50Hz
  • Temperature of Media: -10~80℃ (14℉ to 176℉)
  • Suitable Media: Water, Air, Oil, Gas, etc
  • Material: Brass

Features Of 2W31 Brass Solenoid Valve With LED Light

● Equipped with LED light to let you know the situation easier.

● Available in NPT or G threaded.

● Responsive and long service lifetime.

● IP65 protection solenoid coil.

● Large stock and fast shipping within 3-5 working days.

Technical Parameters Of 2W31 Brass Solenoid Valve With LED Light

Port size 3/8″, 1/2″, 3/4″, 1″, 1¼”, 1½”, 2″ Orifice(mm) 10, 15, 20, 25, 32, 40, 50
Port Thread BSPP, BSPT, NPT Function Normally Closed
Pressure 1.0 MPa (10 bar) Voltage DC-12V, 24V; AC-24V, 120V, 240V/60Hz; 110V, 220V/50Hz
Temperature of Media -10 to 80℃ (14℉ to 176℉) Suitable Media Water, Air, Oil, Gas, etc
Material Brass Applications  Water treatment machine and projects

 

Size Port Size Orifice Cv Min Pressure Max Pressure
AC(22VA) DC(17W)
2W31-10 3/8″ 10 4.5 0.0 MPa 0.7 MPa 0.7 MPa
2W31-15 1/2″ 15 4.5 0.0 MPa 0.7 MPa 0.7 MPa
2W31-20 3/4″ 20 9.3 0.0 MPa 0.7 MPa 0.7 MPa
2W31-25 1″ 25 12 0.0 MPa 0.7 MPa 0.7 MPa
AC(28VA) DC(36W)
2W31-32 1 1/4″ 32 24 0.0 MPa 1.0 MPa 1.0 MPa
2W31-40 1 1/2″ 40 29 0.0 MPa 1.0 MPa 1.0 MPa
2W31-50 2″ 50 48 0.0 MPa 1.0 MPa 1.0 MPa

Dimension Of 2W31 Brass Solenoid Valve

Port Size 3/8”~2” Orifice(mm) 15, 20, 25, 32, 40, 50
Port Thread BSPP, BSPT, NPT, FLANGE Function Normally closed or opened
Pressure 0-1.0 MPa (10 bar) Voltage DC-12V, 24V; AC-24V, 120V, 240V/60Hz; 110V, 220V/50Hz
Temperature of media -10~100℃ (14℉ to 212℉) Suitable Media Water, gas, oil, etc
Material Brass, Stainless Steel Sealing Material NBR, VITON, PTFE, EPDM
Coil S51B,30VA(AC),24W(DC),IP65,100%ED
Coil SD01B,28VA(AC),36W(DC),IP65,100%ED
The actuator on my automated valve operates, but the valve won’t turn. Why?

Most likely the valve stem or actuator coupling is broken.

The electric actuator limit switches or the pneumatic actuator position stops are not correctly adjusted.

Probably because there is no air pressure to the solenoid or dirt has jammed it. Also, debris might be trapped inside the valve. Or, the air pressure is not sufficient to operate the actuator. Remember: measure air pressure at the actuator, not at the compressor.

Maybe. First, be sure that the actuator torque output is sufficient to turn the valve reliably. Second, you will have to fabricate a custom mounting bracket and coupling to connect the actuator to the valve.

The valve will stop somewhere between full open and close. When power is reapplied to the original circuit, the actuator will complete the cycle.

To make the change just remove the actuator from the valve and turn it, or the valve stem, 90 degrees and remount the actuator.

Remove the actuator from the valve and check the valve stem. Most ball valves have stem flats at right angles to the flow when the valve is in the off position. On butterfly valves check the stem flow arrow marking.

Remove the actuator from the valve and check the valve stem. Most ball valves have stem flats at right angles to the flow when the valve is in the off position. On butterfly valves check the stem flow arrow marking.

Check the electric wiring schematic that came with the actuator for the correct hookup. Sometimes a copy is inside the actuator cover. If it is missing, don’t guess about the connections. Call the manufacturer for a schematic.

The actuator is wired incorrectly (check the schematic accompanying the actuator), or the external control switch is not the correct type for the actuator.

Not unless you bought it with an optional speed control.

Actuators and solenoid valves require different types of electrical control switches. SPDT for actuators, SPST for solenoids. Check the actuator wiring schematic for the correct wiring and switch type.